Furniure design
software DESIGN SINTEZ
Cabinets
- Generated multielement units
Partitions
settings
Front,
Back - Decreases
the partitions' depth, changing their position depending on the entered
values. Enables creation of various constructions.The deviations are
entered individually for each partition.
Left distance - This value
defines the position of partitions in the cabinet on its length. On
this
base the program automatically calculates the length of the shelves.
Enter
the position of the partitions for first, second and third one in a
view
front. For first - the distance between the right side of the left
panel to the left side of the first partition. For the second partition
- the distance between the right side of the left panel to the left
side of the second partition and etc.
The structure
for automatic proportional allocation of partitions is kept, too. The
option Proportionately
allocation is active by default. For
unproportionately allocation uncheck the option.
 - This button returns you in
the drawing to measure the necessary distance.
Press the button and specify the distance's two end points. The
measured value will be loaded into the field automatically. This
operation makes easier the setting of the necessary distances
during the partitions' creation.
- The button is activated if the cabinet has two or three partitions and the flag Proportionately allocation is not checked. For a cabinet with two partitions sets the second partition in regular intervals on the basis of entered left distance for the first partition,
thickness of partitions and internal cabinet volume in length. For a
cabinet with three partitions set the third partition on base of the left distances of first and second partitions. FOR
EXAMPLE: We take a cabinet 100 cm long, thickness of end panels and
partitions is 1,8cm. The left distance for first partition is 25
cm. Let's click by the button to allocate the residual volume on
equal parts. In result we receive a position of the second
partition (left distance) 60,70 cm. The distance between the first and
second partitions and between the second partition and right end panel
become identical.
For
a cabinet with three partitions is entered a left distance 25 cm,
for second 55 cm. Let's click by the button to allocate the
residual volume on equal parts. We receive a position of the third
partition (left distance) 75,70 cm. The distance between the second and
third partition and between the third partition and right end panel
become identical.
- The button is activated if the cabinet has three partitions and the flag Proportionately allocation is not checked.
Sets a proportional distance between the second and third
partition on length of a cabinet on the basis of entered distances at
the left for the first partition and the residual volume of a cabinet. FOR
EXAMPLE: We take a cabinet 100 cm long, thickness of end panels and
partitions is 1,8cm. The left distance for first partition is 25 cm.
Let's click by the button to allocate the residual volume on equal
parts. In
result we receive a position of the second partition (distance at the
left) 48,80 cm, and position by third - 72,60 cm. Thus we receive
identical distances between the first and second partition, between the
second and third partition, and as between the third partition and
right end panel.
 |
Enter
a number of partitions. The button Partition
parameters becomes active. The option Proportionaly
allocation is selected by default. Remove the mark from
the option Proportional division
to define manually the position of partitions. Enter the necessary
distances into fields for first,
second and third partition, depending on the specified number: from the
right side of the left end panel to the left side of a respective
partition.
Distances below
and above
- These values define a position of each partition
on the cabinet height and reflect on their height.
|
Options Fixes the position of the
partition in relation to the right end panel of the unit and Scales the distance depending on
the current cabinet dimension - These
two options define the behaviour of the partitions for
unproportionately allocation and next changing of the cabinet
length. They are active for each partition personally. The
options have mutually incompatible action.
- Option Fixes
the position of the
partition in relation to the right end panel of the unit -
If the option is active, when you change the cabinet length, the
distance of the partition from the right end panel doesn't change. The
distance to the left end panel changes.
- Option Scales
the distance depending on the current cabinet dimension -
By
default the position of the partitions after changing of the cabinet
length is fixed to the left end panel. (if
the option Fixes the position
of the partition in relation to the right end panel of the unit is not checked).
If this option is checked, the position of the partition to the left
end panel will change proportionally of the cabinet length change.For
example:
There is a cabinet 100 cm. long with Left
distance of the
partition 30 cm. Let's change the cabinet length on 200 cm. If the
option Scales the distance
depending on the current cabinet dimension is checked , the left distance of the partition
becomes 60 cm. If
the option is not checked the distance will stay 30 cm.
If
there is no checked option, will be
saved the entered left distance of the partitions.
Each
partition can has personal thickness and element nomenclature.If the option to the right of the Thickness
field is checked, the thickness of that partition and its element
nomenclature for material will be doubled. The quantity of its
edgebands will not change.The kind
of the element nomenclature defines by the option Common nomenclature names and layers for
all partitions.
Option
Common
nomenclature names and layers for all partitions
- When the option is active, it sets the generating of cabinet with
common element nomenclatures and layers for all partitions. When it's
not checked each partition has its own personal element nomenclature
for material and layer for rendering. Creates an element nomenclature
for partitions' edgebands, too - Cabinet partitions front
edgeband, Cabinet partitions back edgeband, Cabinet partitions bottom edgeband and Cabinet
partitions top edgeband ( if the option is
checked) or personal for each partition (when the option is not
active) - Cabinet 1st
partition front edgeband, Cabinet 1st partition back edgeband, Cabinet 1st partition top edgeband, Cabinet 1st partition bottom edgeband, Cabinet 2nd partition front edgeband, Cabinet 2nd partition back edgeband, Cabinet 2nd
partition top edgeband, Cabinet 2nd
partition bottom edgeband, Cabinet 3rd partition front edgeband, Cabinet 3rd partition back edgeband, Cabinet 3rd
partition top edgeband, Cabinet 3rd
partition bottom edgeband.
Main
page DS
User guide |