Furniture design software DESIGN SINTEZ

Unit editing

Unit correction

    The operation is intended for correction of the generated units in the current project (modules Cabinets, Corner cabinet, Doors (all models), Blinds - curtains,Additional elements, Worktops (horizontal and wall panel) and Plinths. The work with the module includes 2 basic actions:

  • The button Choice of unit - select a unit from the drawing, which characteristics you want to change. The pressing of the button hides the form and returns you in the drawing to specify a unit on its contour lines. At loading the module the drawing will turn in the View top. If it is necessary to change a view for the best visibility of objects, click on the button to the left of the button Choice of unit. Right click on the image loads all possible views. Left click on a concrete view sets it in the jobs. The repeated right click on a tape with views closes it.<
  • If you have specified unit correctly, press the button Loads unit for correction. The operation will load the program module generating appropriate kind of the chosen unit. You can change all parameters in the window for generating. To set the corrections in unit, click on the button Create in the module. For  cancel  of correction close the window.

When loading the module remembers the last edited cabinet (if it's created by modules Cabinet until you select a new unit using the button Unit name. The purpose of this is the faster and easier editing of cabinets for large drawings in which the selection of the cabinet is difficult because of the big number of units in them.

Generated units without element nomenclatures - The button opens the list of all generated units in the drawing which have not created element nomenclatures.   Regenerating is automatically and at it is activating the option Creates element nomenclature. To edit all units from the list, click Automatic edition of all units (or selected) in the list. To regenerate some units form list, select them and press the same button . The selection is made when the Ctrl is pressed and choice with left mouse button  for  non next rows or with left mouse button dragging  for next rows. Press the button again to close the list.

Full list of generated units -  Loads a list of all generated  units in the job. It contains the name, size and unique code of each unit in it. This allows easy to find unit in big drawings.Click Automatic edition of all units (or selected) in the list to re-generate all units in the list. To regenerate some units only - select them and press the same button.The selection is made when the Ctrl is pressed and choice with left mouse button  for  non next rows or with left mouse button dragging  for next rows. To close the list press the button Full list of generated units again.Operaions that can be proceed for units in this list are: Generating  and Exploded view.

  • Generating- Re-generates and corrects all the units in the list ( or when there are selected re-generate only them).
  • Exploded view  - Re-generates the unit / units in the list ( or only selected) created by Cabinet module and executes screen report Exploded view for each one in a service file.
  • Dimensioning - Re-generates the unit / units in the list ( or only selected) created by Cabinet module and executes screen report Dimension/ The whole unit for each one in a service file.

You can enter a common unique code for the two lists (Full list of generated units and Generated units without element nomenclatures). This code will be set for all units  (or selected in the lists) after their editing.

Automatic edition of all units (or selected) in the list - Automatically starts modules, that generate units  from the list and regenerates them. If in the list there are selected units , only they  will be regenerated. Do selection with pressed Ctrl button and choice with left mouse button for  non next rows or with left mouse button dragging  for next rows. For register  Generated units without element nomenclature , regenerates units and creates element nomenclatures for them.For units created by module Additional elements (with the identifier TА) is necessary to select the option Stops generation for editing for entering of nomenclature name and unit of measure.  The operation don't edit Cornices and Profiles.

Stops generation for editing -  Option defines at regeneration of units from the list ,to load modules, from which they have been created and to can be changed their parameters. When it is inactive, units will regenerate automatically , without possibility for change.

automatic export- Left click on the button automatically extracts and sends the configuration file (.bin) of the selected for editing unit to the service server of Design Sintez. If the list Full list of generated units is loaded, to the server will be sent the configuration files of the the selected in it units or all files (if there are not selected unit in the list).


ENMain page   DS User's guide